fix bug
This commit is contained in:
@@ -672,16 +672,8 @@ class JackeryDataCoordinator:
|
||||
data["calc_batt_net_power"] = p_batt
|
||||
data["calc_battery_charge_power"] = max(0.0, p_batt)
|
||||
data["calc_battery_discharge_power"] = max(0.0, -p_batt)
|
||||
data["calc_grid_net_power"] = p_grid if p_grid is not None else 0 # Return 0 if None for sensor safety?
|
||||
# Note: If p_grid is None, the sensor might show 0 or unavailable.
|
||||
# Ideally "Grid Net Power" sensor should be unavailable if no CT.
|
||||
# But let's set it to 0 for now or handle in sensor.
|
||||
|
||||
# Additional: We might want to pass 'grid_available' to data for sensor state?
|
||||
if p_grid is None:
|
||||
# If we return None, the sensor logic below might error or show Unknown.
|
||||
# Let's leave it as None in data, and handle in sensor update.
|
||||
data["calc_grid_net_power"] = None
|
||||
data["grid_available"] = grid_available
|
||||
data["calc_grid_net_power"] = p_grid if grid_available else None
|
||||
|
||||
except Exception as e:
|
||||
_LOGGER.error(f"Error calculating energy flow: {e}")
|
||||
@@ -862,6 +854,12 @@ class JackerySensor(SensorEntity):
|
||||
|
||||
value = data[json_key]
|
||||
|
||||
if self._sensor_id == "grid_net_power" and value is None:
|
||||
# Keep last value when CT data is temporarily missing
|
||||
self._attr_available = False
|
||||
self.async_write_ha_state()
|
||||
return
|
||||
|
||||
# Process specific conversions
|
||||
if self._sensor_id == "battery_temperature":
|
||||
# cellTemp is 0.1 C
|
||||
|
||||