refactor: update energy flow card configuration for improved clarity and functionality
- Reorganized entity references in the energy flow card configuration, introducing a clearer structure for grid, solar, and battery entities. - Updated sensor mappings for grid consumption and production, battery charge/discharge, and state of charge. - Removed outdated individual entity configurations to streamline the setup.
This commit is contained in:
@@ -465,15 +465,15 @@ class JackeryHomeSensor(SensorEntity):
|
||||
|
||||
## 电池充放电功率 负值为充电,正值为放电
|
||||
## 电网功率 负值为购买,正值为出售
|
||||
# if self._sensor_id == "grid_import_power":
|
||||
# meter_value
|
||||
# elif self._sensor_id == "grid_export_power":
|
||||
# return meter_value if meter_value > 0 else 0
|
||||
if self._sensor_id == "grid_import_power":
|
||||
return abs(meter_value) if meter_value < 0 else 0
|
||||
elif self._sensor_id == "grid_export_power":
|
||||
return meter_value if meter_value > 0 else 0
|
||||
# # 电池功率:同一个 meter_sn,同步更新 battery_charge_power / battery_discharge_power
|
||||
# elif self._sensor_id == "battery_charge_power":
|
||||
# return abs(meter_value) if meter_value < 0 else 0
|
||||
# elif self._sensor_id == "battery_discharge_power":
|
||||
# return meter_value if meter_value > 0 else 0
|
||||
elif self._sensor_id == "battery_charge_power":
|
||||
return abs(meter_value) if meter_value < 0 else 0
|
||||
elif self._sensor_id == "battery_discharge_power":
|
||||
return meter_value if meter_value > 0 else 0
|
||||
if self._sensor_id == "battery_soc":
|
||||
# Battery SOC 需要乘以 0.1 转换为百分比
|
||||
meter_value = meter_value * 0.1
|
||||
|
||||
@@ -1,36 +1,20 @@
|
||||
type: custom:power-flow-card-plus
|
||||
entities:
|
||||
home:
|
||||
entity: sensor.home_power
|
||||
color_icon: solar
|
||||
fossil_fuel_percentage:
|
||||
entity: sensor.battery_soc
|
||||
icon: mdi:pine-tree
|
||||
color_icon: true
|
||||
grid:
|
||||
entity:
|
||||
consumption: sensor.grid_import
|
||||
production: sensor.grid_import
|
||||
display_state: one_way
|
||||
color_circle: true
|
||||
solar:
|
||||
icon: mdi:solar-panel-large
|
||||
entity: sensor.solar_power
|
||||
battery:
|
||||
name: Bateria
|
||||
icon: mdi:bat
|
||||
entity:
|
||||
consumption: sensor.battery_charge_power
|
||||
production: sensor.battery_discharge_power
|
||||
individual:
|
||||
- entity: sensor.grid_import_power
|
||||
icon: mdi:transmission-tower-import
|
||||
color: "#80b8ff"
|
||||
name: Grid Import
|
||||
color_icon: false
|
||||
- entity: sensor.grid_export_power
|
||||
icon: mdi:transmission-tower-export
|
||||
color: "#ff8080"
|
||||
name: Grid Export
|
||||
color_icon: true
|
||||
w_decimals: 0
|
||||
kw_decimals: 2
|
||||
min_flow_rate: 0.9
|
||||
max_flow_rate: 6
|
||||
consumption: sensor.battery_charge
|
||||
production: sensor.battery_discharge
|
||||
state_of_charge: sensor.battery_state_of_charge
|
||||
display_state: one_way
|
||||
color_circle: true
|
||||
home:
|
||||
color_icon: true
|
||||
watt_threshold: 10000
|
||||
clickable_entities: true
|
||||
title: Power Flow Card Plus
|
||||
Reference in New Issue
Block a user